{"product_id":"honeywell-fc-ro-1024-redundant-output-module-sil-3-compliant-safety-module","title":"Honeywell FC-RO-1024 | Redundant Output Module | SIL 3 Compliant Safety Module","description":"\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan\u003eShopify Product Title\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHoneywell FC-RO-1024 | Redundant Output Module | Safety Manager | SIL 3 Compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FC-RO-1024\u003c\/span\u003e is a high-performance redundant output module specifically designed for integration into Honeywell's Safety Manager and Fail Safe Control (FSC) systems. With its dual-channel architecture, it ensures system reliability by offering redundant relay outputs for safety-critical applications. The module is ideal for use in safety-instrumented systems (SIS), particularly where high reliability and compliance with SIL 3 (Safety Integrity Level) are required.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundant Relay Outputs\u003c\/span\u003e: The module offers 10 redundant relay channels, with each channel configured to guarantee continuous safe operation even in the event of a component failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGalvanic Isolation\u003c\/span\u003e: Electrical isolation between the module’s electronics and field devices enhances safety and system integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-Swappable\u003c\/span\u003e: The FC-RO-1024 supports online replacement without disrupting system operation, provided the baseplate and partner module are properly configured.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostics \u0026amp; Monitoring\u003c\/span\u003e: Integrated loop monitoring and self-test features report the health status of the output circuit, ensuring continuous operational safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSIL 3 Certified\u003c\/span\u003e: Compliant with Safety Integrity Level 3 standards, making it suitable for emergency shutdown (ESD), fire and gas (F\u0026amp;G) systems, and other critical safety functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFC-RO-1024\u003c\/span\u003e (or \u003cspan\u003e1024\/1\/1\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Redundant Relay Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Contact Relay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e36 Vdc \/ 250 Vac (depending on load type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A per Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic Isolation between Electronics and Field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSuitable for SIL 3 Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 W (typical) at 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +70°C (+14°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44096012615779,"sku":"FC-RO-1024","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/FC-RO-1024-2.jpg?v=1775023431","url":"https:\/\/precisemodule.com\/products\/honeywell-fc-ro-1024-redundant-output-module-sil-3-compliant-safety-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}