{"product_id":"honeywell-fc-sao-0220m-safe-analog-output-module","title":"Honeywell FC-SAO-0220M Safe Analog Output Module","description":"\u003cp\u003e\u003cspan\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FC-SAO-0220M\u003c\/span\u003e is a high-integrity \u003cspan\u003eSafe Analog Output Module\u003c\/span\u003e designed for use with Honeywell’s \u003cspan\u003eSafety Manager\u003c\/span\u003e and \u003cspan\u003eSafety Manager SC\u003c\/span\u003e systems (formerly \u003cspan\u003eFail-Safe Control \/ FSC\u003c\/span\u003e). As part of a \u003cspan\u003eSafety Instrumented System (SIS)\u003c\/span\u003e, it is certified for use in safety loops up to \u003cspan\u003eSIL 3\u003c\/span\u003e according to \u003cspan\u003eIEC 61508\u003c\/span\u003e, providing precise and reliable control for applications that require modulating output signals.\u003c\/p\u003e\n\u003cp\u003eThis module offers \u003cspan\u003e2 independent analog output channels\u003c\/span\u003e with a \u003cspan\u003e4–20 mA\u003c\/span\u003e signal, making it ideal for controlling final control elements such as \u003cspan\u003emodulating control valves\u003c\/span\u003e or \u003cspan\u003evariable speed drives\u003c\/span\u003e in safety-critical environments. The \u003cspan\u003eFC-SAO-0220M\u003c\/span\u003e includes extensive \u003cspan\u003einternal diagnostics\u003c\/span\u003e to ensure output integrity and to drive the output to a \u003cspan\u003epre-defined Safe State\u003c\/span\u003e in case of discrepancies.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSIL 3 Certification\u003c\/span\u003e: Fully certified for use in \u003cspan\u003eSIL 3 safety loops\u003c\/span\u003e, ensuring compliance with industry safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrecise Output Control\u003c\/span\u003e: Provides \u003cspan\u003e4–20 mA\u003c\/span\u003e analog output with a \u003cspan\u003e12-bit resolution\u003c\/span\u003e and \u003cspan\u003e±0.1%\u003c\/span\u003e accuracy, ensuring accurate control of safety-critical systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafe State Protection\u003c\/span\u003e: Configurable fail-safe behavior for output channels, including \u003cspan\u003e0 mA\u003c\/span\u003e, \u003cspan\u003e\u0026lt; 3.6 mA\u003c\/span\u003e, or \u003cspan\u003eHold Last Value\u003c\/span\u003e to prevent unsafe operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh Availability\u003c\/span\u003e: Supports \u003cspan\u003eredundant configurations (1oo2)\u003c\/span\u003e, allowing continuous operation even if one module fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-Swappable\u003c\/span\u003e: Designed for \u003cspan\u003eonline replacement\u003c\/span\u003e, enabling maintenance without disrupting the safety system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHART Compatibility\u003c\/span\u003e: Often supports \u003cspan\u003eHART pass-through\u003c\/span\u003e, allowing communication with smart field instruments for enhanced diagnostics and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCorrosion Protection\u003c\/span\u003e: Features a \u003cspan\u003eG3 conformal coating\u003c\/span\u003e, ensuring durability in harsh industrial environments like oil rigs and chemical refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (0-22 mA for over-range\/under-range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit (minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 600Ω at 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Integrity Level (SIL)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRead-back Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous loop monitoring for fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafe State\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable (e.g., 0 mA, \u0026lt; 3.6 mA, Hold Last Value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eDetects open circuits and short circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (module dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field-side and internal bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRUN (Green), FAIL (Red), CH1\/CH2 (Channel Status LEDs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 1U width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eApplication Areas:\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eFC-SAO-0220M\u003c\/span\u003e is ideal for use in industries where precise analog output control is essential for safety-critical operations, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; Gas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical Processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRefining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the maximum load impedance supported by the FC-SAO-0220M?\u003c\/span\u003e\u003cbr\u003eA: The module can support \u003cspan\u003eloads up to 600Ω\u003c\/span\u003e at \u003cspan\u003e24V DC\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How does the module ensure safety in case of discrepancies in the output signal?\u003c\/span\u003e\u003cbr\u003eA: The module continuously monitors the output current and can drive the output to a \u003cspan\u003epre-defined Safe State\u003c\/span\u003e if the read-back value deviates beyond the acceptable tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the module be replaced without shutting down the system?\u003c\/span\u003e\u003cbr\u003eA: Yes, the \u003cspan\u003eFC-SAO-0220M\u003c\/span\u003e is \u003cspan\u003ehot-swappable\u003c\/span\u003e, allowing safe replacement while the system remains operational.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44092740763747,"sku":"FC-SAO-0220m","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/FC-SAO-0220m.jpg?v=1774953047","url":"https:\/\/precisemodule.com\/products\/honeywell-fc-sao-0220m-safe-analog-output-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}