{"product_id":"honeywell-fc-sdo-0824-digital-output-module-safety-manager-sil-3","title":"Honeywell FC-SDO-0824 Digital Output Module | Safety Manager SIL 3","description":"\u003cp\u003e\u003cspan\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FC-SDO-0824\u003c\/span\u003e is a high-safety Digital Output Module designed for integration with Honeywell's \u003cspan\u003eSafety Manager\u003c\/span\u003e and \u003cspan\u003eSafety Manager SC\u003c\/span\u003e systems, formerly known as \u003cspan\u003eFail-Safe Control (FSC)\u003c\/span\u003e. As an essential component of \u003cspan\u003eSafety Instrumented Systems (SIS)\u003c\/span\u003e, it ensures reliable control of final elements such as solenoid valves, motors, and emergency shutdown (ESD) devices, critical to maintaining process safety in high-integrity applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cspan\u003eFC-SDO-0824\u003c\/span\u003e is certified for use in \u003cspan\u003eSIL 3\u003c\/span\u003e safety loops, offering robust performance, safety diagnostics, and extensive fault tolerance. The module supports \u003cspan\u003e8 independent digital output channels\u003c\/span\u003e, each capable of handling \u003cspan\u003e24 VDC\u003c\/span\u003e loads up to \u003cspan\u003e2A\u003c\/span\u003e per channel, making it ideal for complex safety systems that require precise, fail-safe operation.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-Safety SIL 3 Certification\u003c\/span\u003e: Suitable for high-integrity safety loops, meeting the strict requirements of IEC 61508 for \u003cspan\u003eSIL 3\u003c\/span\u003e applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy \u0026amp; Fault Tolerance\u003c\/span\u003e: Supports \u003cspan\u003e1oo2\u003c\/span\u003e (one-out-of-two) redundancy configurations, enhancing system availability and fault tolerance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShort-Circuit Protection\u003c\/span\u003e: Each channel features built-in short-circuit protection, automatically shutting down the affected channel to prevent damage to the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-Swappable\u003c\/span\u003e: Designed for \u003cspan\u003ehot-swap\u003c\/span\u003e functionality, allowing for safe module replacement without system shutdown (with a redundant partner active).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous Self-Test\u003c\/span\u003e: The module continuously self-tests its output transistors and read-back circuitry, ensuring that output states remain correct and safe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExtensive Diagnostics\u003c\/span\u003e: Integrated diagnostics include line monitoring for open circuits and short circuits, ensuring any wiring issues are immediately detected and reported.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Channels (Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Current per Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Total Module Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e15A (Limited by backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLeakage Current (Off State)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Integrity Level (SIL)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5W (logic) + load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2500 VDC between field signals and internal safety bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\/Green\/Yellow LEDs for each channel (indicates channel state and faults)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C (Cabinet Mount)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eG3 Conformal Coating (for harsh environments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSafety \u0026amp; Diagnostics:\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFail-Safe Operation\u003c\/span\u003e: In the event of module failure or communication loss, all outputs are de-energized (turned OFF) by default, maintaining system safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLine Monitoring\u003c\/span\u003e: Constantly checks for open or short circuits in field wiring, providing real-time monitoring and alerts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInternal Diagnostics\u003c\/span\u003e: Performs self-tests on output transistors and other internal components to ensure correct functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Areas:\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eFC-SDO-0824\u003c\/span\u003e is widely used in industries where process safety is critical, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; Gas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical Processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the maximum load currentFC-SDO-O824 per channel?\u003c\/span\u003e\u003cbr\u003eA: Each output channel can handle up to \u003cspan\u003e2A\u003c\/span\u003e of current at \u003cspan\u003e24 VDC\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the module be replaced without shutting down the system?\u003c\/span\u003e\u003cbr\u003eA: Yes, the \u003cspan\u003eFC-SDO-0824\u003c\/span\u003e supports hot-swapping, allowing it to be replaced while the system is online (with redundancy configured).\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How does the module ensure safety in case of a failure?\u003c\/span\u003e\u003cbr\u003eA: In case of a failure or loss of communication, all outputs default to a \u003cspan\u003ede-energized (OFF) state\u003c\/span\u003e, maintaining fail-safe operation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44092738109539,"sku":"FC-SDO-O824","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/05701-A-0282.jpg?v=1774951838","url":"https:\/\/precisemodule.com\/products\/honeywell-fc-sdo-0824-digital-output-module-safety-manager-sil-3","provider":"Precise Module Ltd.","version":"1.0","type":"link"}