{"product_id":"honeywell-fs-tsdo-0824-sil-2-8-channel-safe-digital-output-module","title":"Honeywell FS-TSDO-0824 SIL 2 8-Channel Safe Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FS-TSDO-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity digital output module engineered for safety-critical automation systems. Designed for integration within the Honeywell Safety Manager (Fail Safe) architecture, this module provides 8 isolated output channels capable of controlling solenoids, actuators, and relays while maintaining fail-safe operation. It is certified for SIL 2 and ensures that any fault condition forces outputs to a predefined safe state.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Reliability and Diagnostics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitors internal circuits and field wiring for shorts, open circuits, and cross-channel interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes watchdog timers for self-checking critical components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostic LEDs for Run, Fail, and individual channel status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 independent digital output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal voltage: 24 VDC (maximum 36 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent capacity: up to 2 A per channel (load-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanic isolation between logic and field circuits for surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFail-Safe and Redundancy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExecutes automatic safe shutdown on communication loss or critical fault\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports redundant pairing for increased system availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable in redundant configurations to minimize downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: -40°C to +75°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail (TS32 \/ TS35 x 7.5) or panel mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust against electromagnetic interference (EMI) and harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact dimensions: 60 × 70 × 58 mm (D × W × H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Table\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eModule Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eFail-Safe Digital Output (TSDO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eChannels\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax Voltage\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eUp to 2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSIL 2 certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHigh-speed switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDiagnostics\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eIntegrated channel and system monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eIsolation\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eGalvanic separation between field and logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMounting\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDIN rail TS32\/TS35 x 7.5, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDimensions\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e60 × 70 × 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-TSDO-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for critical SIS loops including Emergency Shutdown (ESD), Fire and Gas (F\u0026amp;G), and other high-integrity process control systems. Its fast, reliable outputs and fail-safe design make it ideal for scenarios requiring SIL-certified operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used in SIL 3 systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it can be configured in redundant pairs to meet higher SIL requirements, although individually it is SIL 2 certified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it safe to replace this module while the system is running?\u003c\/strong\u003e\u003cbr\u003eA: Hot-swapping is supported only when configured redundantly to maintain continuous operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What loads can each output channel drive?\u003c\/strong\u003e\u003cbr\u003eA: Each channel supports up to 2 A, suitable for solenoids, relays, and small actuators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I monitor the module status?\u003c\/strong\u003e\u003cbr\u003eA: Front-panel LEDs indicate system Run, Fail, and individual channel conditions for rapid diagnostics.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44144215654499,"sku":"FS-TSDO-0824","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/HONEYWELLFS-TSDO-0824-3.jpg?v=1777284723","url":"https:\/\/precisemodule.com\/products\/honeywell-fs-tsdo-0824-sil-2-8-channel-safe-digital-output-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}