{"product_id":"honeywell-fsc-10004-1-1-communication-module","title":"Honeywell FSC 10004\/1\/1 Communication Module","description":"\u003ch1\u003eHoneywell 10004\/1\/1 Communication Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 10004\/1\/1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e10004\/1\/1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Module) provides direct communication exchange within Honeywell FSC and Fault Tolerant Automation architectures. Operating as a vertical communication interface, the module manages data transfer between safety controllers, communication networks, and associated system components while supporting multiple industrial communication media.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10004\/1\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eFSC and FTA Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Channels\u003c\/td\u003e\n\u003ctd\u003eDual-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Types\u003c\/td\u003e\n\u003ctd\u003eRS232C, RS422, RS485, TTY Current Loop, Fiber Optic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e1150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Width\u003c\/td\u003e\n\u003ctd\u003e8 TE \/ 8 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e3 HE \/ 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eEurocard Plug-in Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eSIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eCE, TÜV Rheinland, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eBased on 8 HP Eurocard format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 1150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSIL 3 Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 10004\/1\/1 module is designed for deployment within Honeywell FSC safety systems where deterministic communication and fault-tolerant operation are required. The module supports safety-related communication tasks while maintaining compatibility with SIL 3 system architectures.\u003c\/p\u003e\n\u003cp\u003eDual communication channels enable independent communication paths for controller interaction and system integration functions. The architecture supports communication between safety controllers, operator stations, supervisory systems, and external industrial devices.\u003c\/p\u003e\n\u003cp\u003eThe module forms part of the communications infrastructure within FSC and FTA platforms and is intended for operation within certified safety-related installations.\u003c\/p\u003e\n\u003ch3\u003eGalvanic Isolation and Multi-Protocol Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe communication platform supports multiple physical interface technologies, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRS232C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRS422\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRS485\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTTY Current Loop\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiber Optic Networks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis flexibility allows integration with both legacy and modern industrial communication infrastructures. Depending on the installed communication configuration, the module can be adapted for serial communication, long-distance communication links, or fiber-based network connections.\u003c\/p\u003e\n\u003cp\u003eWithin FSC architectures, communication processing operates independently from safety logic execution, helping maintain deterministic behavior throughout the control system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many communication channels are supported by the module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10004\/1\/1 provides dual-channel communication capability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which communication interfaces are available?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupported interfaces include RS232C, RS422, RS485, current loop (TTY), and fiber optic communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module suitable for safety-related applications?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The module is specified for systems certified up to SIL 3 and is used within FSC and FTA safety architectures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify compatibility with the installed FSC or FTA system revision before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm rack space availability for the 8 HP, 3U Eurocard form factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the system power supply can support the specified 5 VDC, 1150 mA requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute communication cables separately from high-current power wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply signal grounding and shielding practices according to site communication standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify communication media selection matches the configured interface type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform communication diagnostics and channel verification after commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67675698692195,"sku":"10004\/1\/1","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/10004-H-F_2.png?v=1791537513","url":"https:\/\/precisemodule.com\/products\/honeywell-fsc-10004-1-1-communication-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}