{"product_id":"honeywell-mc-pdoy22-80363975-150-digital-output-module","title":"Honeywell MC-PDOY22 80363975-150 Digital Output Module","description":"\u003ch2\u003eHoneywell 80363975-150 MC-PDOY22 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 80363975-150\u003c\/strong\u003e (\u003cstrong\u003e80363975\u003c\/strong\u003e Digital Output Module) operates as a dedicated output interface for discrete field device control within Honeywell distributed control systems. The module provides 32 digital output channels for switching external loads and executing command signals between the controller and field equipment.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e80363975-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMC-PDOY22 Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOP Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output (DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e32 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage Range\u003c\/td\u003e\n\u003ctd\u003e15 VDC to 30 VDC (FTA OY22,62)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC \/ 125 VDC (FTA OY23,63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eHoneywell Digital Output I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eRack\/Chassis-mounted I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Alternative Part Number\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDigital Output Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe MC-PDOY22 module provides 32 discrete output channels for interfacing with field actuators, relays, annunciators, and interposing control devices. Output signals are transmitted from the control processor to external equipment through compatible Honeywell field termination assemblies (FTAs).\u003c\/p\u003e\n\u003ch3\u003eChannel Isolation and Field Interface\u003c\/h3\u003e\n\u003cp\u003eWithin a DCS architecture, digital output modules serve as the electrical interface between control logic and field devices. Proper field termination selection is required according to the applied load voltage and output configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output channels are provided by the module?\u003c\/strong\u003e\u003cbr\u003eA: The MC-PDOY22 supports 32 digital output channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What load voltage range is supported with OY22\/OY62 FTAs?\u003c\/strong\u003e\u003cbr\u003eA: The specified load voltage range is 15 VDC to 30 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be used with AC loads?\u003c\/strong\u003e\u003cbr\u003eA: Yes. A maximum load rating of 250 VAC is specified when used with compatible OY23\/OY63 field termination assemblies.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify module compatibility with the designated Honeywell I\/O rack before installation.\u003c\/li\u003e\n\u003cli\u003eIsolate system power before inserting or removing field wiring connections.\u003c\/li\u003e\n\u003cli\u003eSeparate output wiring from communication and low-level signal cables.\u003c\/li\u003e\n\u003cli\u003eConfirm correct FTA selection based on load voltage requirements.\u003c\/li\u003e\n\u003cli\u003eInspect terminal tightness and grounding continuity prior to commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46216232108131,"sku":"MC-PDOY22 80363975-150","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/MC-PDIX0251304485-150_6.jpg?v=1789531309","url":"https:\/\/precisemodule.com\/products\/honeywell-mc-pdoy22-80363975-150-digital-output-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}