{"product_id":"honeywell-mc-taih02-51304453-150-high-level-analog-input-sti-fta","title":"Honeywell MC-TAIH02 51304453-150 High Level Analog Input\/STI FTA","description":"\u003ch2\u003eHoneywell MC-TAIH02 51304453-150 High Level Analog Input\/STI FTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TAIH02 51304453-150\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-TAIH02\u003c\/strong\u003e High Level Analog Input\/STI FTA, operates as a dedicated hardware component for field signal termination and conditioning within Experion PKS and TDC 3000 DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH02 \/ 51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FTA board layout (304 mm x 122 mm approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC system power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input (4-20 mA, 1-5 VDC) \/ STI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000, Experion PKS (MC-PAIH03 IOP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface\u003c\/td\u003e\n\u003ctd\u003eMulti-conductor FTA interface cable to I\/O Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and 4-20 mA HART Loop Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eField Termination Assemblies (FTAs) provide pass-through signal routing and current loop power distribution for 16-channel analog input cards. The board maintains 4-20 mA HART loop protocol signal integrity by filtering high-frequency noise while allowing bi-directional digital frequency-shift keying (FSK) communication between field transmitters and process controllers. Integrated channel-to-channel isolation networks prevent field wiring noise, ground potential differences, and common-mode voltage spikes from corrupting central I\/O processor calculations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the MC-TAIH02 FTA provide loop power to 2-wire field transmitters?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When connected to a 24 VDC power distribution source, the FTA routes system loop power directly to the individual field terminals for 2-wire 4-20 mA transmitters.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swappable replacement supported for the multi-conductor cable connecting to the MC-PAIH03 IOP?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The interface cable can be disconnected and reconnected while the system is powered, provided field loop connections are safely monitored during the maintenance window.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the FTA securely onto standard DIN-rail assemblies inside the termination cabinet, verifying that grounded metal DIN clips make solid electrical contact with the panel backplate.\u003c\/li\u003e\n\u003cli\u003eStrip field signal wire insulation to recommended lengths and torque screw terminal connectors to specified rating (typically 0.5 to 0.6 Nm) to avoid loose wire faults.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC redundant power wiring separately from high-level analog signal cables to prevent inductive coupling and transient noise propagation.\u003c\/li\u003e\n\u003cli\u003eEnsure shield drain wires from 4-20 mA field cables are tied to the cabinet single-point ground bar and left floating\/insulated at the field instrument enclosure.\u003c\/li\u003e\n\u003cli\u003eConnect the multi-conductor interface cable between the FTA terminal socket and the corresponding MC-PAIH03 I\/O processor board, ensuring side locking clips fully engage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46226771574883,"sku":"MC-TAIH02 51304453-150","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/MC-TAIH02_2.png?v=1790062433","url":"https:\/\/precisemodule.com\/products\/honeywell-mc-taih02-51304453-150-high-level-analog-input-sti-fta","provider":"Precise Module Ltd.","version":"1.0","type":"link"}