{"product_id":"honeywell-mc-taoy22-80366177-175-analog-output-module","title":"Honeywell MC-TAOY22 80366177-175 Analog Output Module","description":"\u003ch1\u003eHoneywell 80366177-175 MC-TAOY22 Analog Output Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for analog signal transmission within Honeywell distributed control system architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 80366177-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eMC-TAOY22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output Module) provides direct generation of field control signals from controller logic to external devices. The module supports multiple independent analog channels, 4-20 mA current loop outputs, optional voltage output configurations, and integration with Honeywell UCN, Experion PKS, HPM, and TDC 3000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e80366177-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMC-TAOY22 Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 independent analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Output Range\u003c\/td\u003e\n\u003ctd\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Output\u003c\/td\u003e\n\u003ctd\u003e24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Output Type\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC software-selectable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Compliant Voltage\u003c\/td\u003e\n\u003ctd\u003e15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Impedance\u003c\/td\u003e\n\u003ctd\u003e750 Ohm at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit to 16-bit D\/A conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.35% at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Variation Accuracy\u003c\/td\u003e\n\u003ctd\u003eUp to ±0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Settling Time\u003c\/td\u003e\n\u003ctd\u003e4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Loop Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eCompression terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Size\u003c\/td\u003e\n\u003ctd\u003eSize B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 30.7 cm x 12.1 cm x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Operating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C37.90.1-1978 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell UCN, Experion PKS, HPM, TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Analog Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe MC-TAOY22 module is designed for multi-channel analog signal generation within Honeywell process control environments. Independent analog output channels support distribution of control signals to final control elements, recorders, and interface equipment. Proper field wiring practices, load impedance management, and cabinet grounding arrangements contribute to stable current-loop performance and minimize susceptibility to externally induced electrical noise. The module supports high-density analog control applications where multiple outputs operate simultaneously within a common DCS infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output types are supported by the MC-TAOY22 module?\u003c\/strong\u003e\u003cbr\u003eA: The primary output format is 4-20 mA current loop operation. Certain configurations also support software-selectable 0-10 VDC output operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum supported load impedance?\u003c\/strong\u003e\u003cbr\u003eA: The module supports resistive loads up to 750 Ohm at a 20 mA output level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support redundant system architectures?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The supplied documentation identifies support for standby and redundant connection arrangements within compatible Honeywell control system configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify field device current requirements before connecting output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm total loop resistance remains within specified output compliance limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute analog output wiring separately from AC power and motor feeder circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded instrumentation cables where required by site engineering standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate cable shields according to the facility grounding philosophy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect compression terminal connections for proper conductor retention before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify output scaling and range configuration within the host control system before placing field devices into operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain adequate cabinet ventilation and environmental conditions consistent with Honeywell installation requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67586659254371,"sku":"MC-TAOY22 80366177-175","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/7bd912a7a3cf51b27150c38ae35222d9.jpg?v=1719908449","url":"https:\/\/precisemodule.com\/products\/honeywell-mc-taoy22-80366177-175-analog-output-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}