{"product_id":"honeywell-mu-taih22-80366195-100-high-level-analog-input-fta","title":"Honeywell MU-TAIH22 80366195-100 High-Level Analog Input FTA","description":"\u003ch1\u003eHoneywell 80366195-100 MU-TAIH22 High-Level Analog Input FTA\u003c\/h1\u003e\n\u003cp\u003eConfigured for analog signal termination in Honeywell TPS and DCS architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 80366195-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eMU-TAIH22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-Level Analog Input FTA) provides direct field wiring termination and signal routing for high-level analog inputs and Smart Transmitter Interface (STI) channels. The assembly supports 16 analog input channels and serves as the interface between field transmitters and Honeywell I\/O processors.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e80366195-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH22 High-Level Analog Input FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTA Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input \/ STI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Analog Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10 V to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eHoneywell TPS and DCS Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eField signal termination and routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAnalog Signal Interface\u003c\/h3\u003e\n\u003cp\u003eThe MU-TAIH22 functions as a field termination assembly for high-level analog signals and Smart Transmitter Interface channels. It routes transmitter signals from field wiring to the associated Honeywell analog input processor while providing organized termination points for maintenance and commissioning activities.\u003c\/p\u003e\n\u003ch3\u003e4-20 mA and Analog Signal Integration\u003c\/h3\u003e\n\u003cp\u003eThe module is designed for integration with process instrumentation systems where analog measurements are collected and transferred to Honeywell control processors. The FTA supports signal routing for monitoring applications requiring stable analog signal transmission between field devices and the DCS infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many analog input channels are supported?\u003c\/strong\u003e\u003cbr\u003eA: The MU-TAIH22 provides 16 dedicated analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input signal range is supported?\u003c\/strong\u003e\u003cbr\u003eA: The specified input range is -10 V to +10 V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What supply voltage is required?\u003c\/strong\u003e\u003cbr\u003eA: The assembly operates from a 24 VDC supply.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the FTA securely on a standard DIN rail inside the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate analog signal wiring from high-voltage power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify terminal identification before connecting field transmitters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain proper shield grounding practices for low-level analog circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect all termination points before energizing the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46216257339491,"sku":"MU-TAIH22 80366195-100","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/MC-PDIX0251304485-150_4.jpg?v=1789531309","url":"https:\/\/precisemodule.com\/products\/honeywell-mu-taih22-80366195-100-high-level-analog-input-fta","provider":"Precise Module Ltd.","version":"1.0","type":"link"}