{"product_id":"honeywell-mu-tpix12-51304084-125-pulse-input-high-level-termination-module","title":"Honeywell MU-TPIX12 51304084-125 Pulse Input High Level Termination Module","description":"\u003ch2\u003eHoneywell MU-TPIX12 51304084-125 Pulse Input High Level Termination Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-TPIX12 51304084-125\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-TPIX12\u003c\/strong\u003e Pulse Input Termination Module, serves as an 8-channel pulse input interface for high-level signal acquisition within Honeywell HPM, APM, and PM architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eMU-TPIX12 (51304084-125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e~0.62 kg (board only) to ~1.17 kg (packaged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e2.8 cm × 37.8 cm × 27.8 cm (12 in length category)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003eUp to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Channels\u003c\/th\u003e\n\u003ctd\u003e8 pulse input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Types\u003c\/th\u003e\n\u003ctd\u003eRectangular or sine wave pulses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Frequency\u003c\/th\u003e\n\u003ctd\u003e1 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Impedance\u003c\/th\u003e\n\u003ctd\u003e≥10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse Thresholds\u003c\/th\u003e\n\u003ctd\u003eLow: -0.5 V to +1.9 V; High: +3.5 V to +24 V (hysteresis between 1.9–3.5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Pulse Width\u003c\/th\u003e\n\u003ctd\u003e25 µs at 20 kHz (IOP filter jumper storage); 50 µs at 10 kHz (IOP filter H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eInterfaces with MU-PPIX02 IOP via MU-KFTAxx cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003ctd\u003eCompression-type terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Coating\u003c\/th\u003e\n\u003ctd\u003eNon-conformally coated (MC-TPIX12 variant provides conformal coating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eAlthough designed for pulse acquisition, the MU-TPIX12 integrates into Honeywell subsystems where mixed analog and pulse signals coexist. Channel-to-channel isolation is maintained through input impedance and hysteresis thresholds, preventing false triggers and ensuring deterministic pulse capture. This design supports stable interfacing with smart transmitters and high-frequency pulse sources.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the MU-TPIX12 handle sine wave signals directly? A: Yes. Both rectangular and sine wave pulses are supported within the specified frequency range.\u003c\/p\u003e\n\u003cp\u003eQ: What happens if pulse width is below the minimum threshold? A: Pulses shorter than the specified dwell time may not register reliably, leading to missed counts.\u003c\/p\u003e\n\u003cp\u003eQ: Is redundancy available on this module? A: No. Redundancy is not supported; for environments requiring redundancy, alternate FTA models must be used.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in designated termination slots with proper mechanical engagement.\u003c\/li\u003e\n\u003cli\u003eEnsure compression terminals are tightened to manufacturer torque specifications.\u003c\/li\u003e\n\u003cli\u003eRoute pulse input wiring separately from high-voltage conductors to minimize interference.\u003c\/li\u003e\n\u003cli\u003eConfigure IOP filter jumper positions according to expected pulse frequency ranges.\u003c\/li\u003e\n\u003cli\u003eGround shielded cabling at a single point to prevent circulating currents.\u003c\/li\u003e\n\u003cli\u003eVerify environmental conditions meet specified operating and storage ranges.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44622990147683,"sku":"MU-TPIX12 51304084-125","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/51304084-175MC-TPIX12_1.png?v=1789459592","url":"https:\/\/precisemodule.com\/products\/honeywell-mu-tpix12-51304084-125-pulse-input-high-level-termination-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}