{"product_id":"honeywell-searchpoint-2106b2312-atex-sensepoint-ht-flammable-gas-sensor","title":"Honeywell Searchpoint 2106B2312 ATEX Sensepoint HT Flammable Gas Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 2106B2312\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance flammable gas detector from the Searchpoint Optima Plus series, designed for hazardous industrial environments. This infrared (IR) point detector measures hydrocarbon gas concentrations, providing accurate readings from 0–20% or 0–100% LEL, depending on control configuration. Its robust design and advanced IR sensing technology make it highly resistant to chemical interference, reducing the need for frequent recalibration.\u003c\/p\u003e\n\u003cp\u003eEngineered for harsh conditions, the 2106B2312 features a 316 stainless steel enclosure, wide operating temperature range, and rapid response to gas leaks, making it ideal for critical safety applications in oil \u0026amp; gas, chemical, and wastewater processing facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Infrared Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual-beam, dual-compensated sensor ensures high accuracy and stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistant to catalytic sensor “poisoning” from silicones, halides, and sulfides\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous internal self-checks detect optical or electronic faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFast and Sensitive Response\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eT60 \u0026lt; 6 seconds, T90 \u0026lt; 10 seconds ensures quick detection of hazardous gases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDynamic heating of optics prevents condensation, fogging, or false alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum alarm level set at 5% LEL for early warning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRobust and Reliable Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e316 stainless steel housing suitable for offshore, coastal, and industrial atmospheres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCertified for ATEX Zone 1\/2, IECEx, and other international standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperates across -55°C to +150°C (-67°F to +302°F) and 20–90% RH continuous humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Flexibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 3\/4 NPT or M25 entries depending on model configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow power consumption of 0.7 W at 200 mA ensures energy-efficient operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput signal uses a mV bridge for accurate control system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e2106B2312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSensepoint HT Flammable Sensor (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDetection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0–20% LEL \/ 0–100% LEL (Control card dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eT60 \u0026lt;6 s, T90 \u0026lt;10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMinimum Alarm Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003emV bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e220 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-55°C to +150°C (-67°F to +302°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eContinuous: 20–90% RH, Intermittent: 10–99% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e75–110 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.7 W at 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; Gas Platforms and FPSOs for hydrocarbon leak detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical processing plants monitoring flammable vapor concentrations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine enclosures for fuel leak detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWastewater treatment facilities monitoring methane accumulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2106B2312\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically mounted with a 3\/4 NPT or M25 thread and calibrated for specific gases like Methane or Propane. Ensure the calibration label matches the intended gas before installation. Its rugged IR sensor design reduces the need for routine maintenance and calibration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How resistant is the 2106B2312 to environmental interference?\u003c\/strong\u003e\u003cbr\u003eA: The dual-beam IR technology prevents false readings from chemical \"poisons,\" condensation, and dust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the typical response time to gas leaks?\u003c\/strong\u003e\u003cbr\u003eA: T60 is less than 6 seconds, and T90 is under 10 seconds, ensuring fast detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this sensor operate in extreme temperatures?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it functions from -55°C to +150°C (-67°F to +302°F).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is calibration required frequently?\u003c\/strong\u003e\u003cbr\u003eA: No, the dual-compensated IR design minimizes the need for frequent recalibration.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44118772154467,"sku":"2106B2312","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/HONEYWELL2106B2312.jpg?v=1776232631","url":"https:\/\/precisemodule.com\/products\/honeywell-searchpoint-2106b2312-atex-sensepoint-ht-flammable-gas-sensor","provider":"Precise Module Ltd.","version":"1.0","type":"link"}