{"product_id":"honeywell-tc-ixl061-thermocouple-input-module","title":"Honeywell TC-IXL061 Thermocouple Input Module","description":"\u003ch2\u003eHoneywell TC-IXL061 Thermocouple Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-IXL061\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-IXL061\u003c\/strong\u003e Thermocouple Input Module, operates as a dedicated hardware component for thermocouple signal acquisition within Honeywell process control systems. The module provides six isolated input channels for direct connection of multiple thermocouple types, supporting temperature measurement, signal conversion, and controller data acquisition functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IXL061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e96978480 A01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e6 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensor Types\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, C, R, S, B thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ms (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMRR\u003c\/td\u003e\n\u003ctd\u003eGreater than 120 dB at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNMRR\u003c\/td\u003e\n\u003ctd\u003eGreater than 70 dB at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 5.1 VDC\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 24 VDC\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 % to 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 4.28 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe TC-IXL061 is designed for direct thermocouple measurement applications requiring multiple independent temperature input channels. The module supports common industrial thermocouple standards including J, K, T, E, C, R, S, and B types.\u003c\/p\u003e\n\u003cp\u003eThe measurement architecture incorporates channel isolation between field inputs and the control system backplane. This isolation structure assists in reducing ground loop effects and electrical interference between connected measurement points. Thermocouple input modules of this class utilize cold junction compensation techniques to maintain temperature measurement accuracy across varying ambient conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many thermocouple channels are available on the module?\u003c\/strong\u003e\u003cbr\u003eA: The TC-IXL061 provides six independent thermocouple input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What thermocouple sensor types are supported?\u003c\/strong\u003e\u003cbr\u003eA: The module supports J, K, T, E, C, R, S, and B thermocouple types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module provide electrical isolation?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module provides 1500 VAC isolation between field-side signals and system electronics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse the correct thermocouple type configuration for each channel.\u003c\/li\u003e\n\u003cli\u003eRoute thermocouple wiring separately from power conductors.\u003c\/li\u003e\n\u003cli\u003eMaintain polarity throughout field wiring connections.\u003c\/li\u003e\n\u003cli\u003eGround cable shields according to site instrumentation practices.\u003c\/li\u003e\n\u003cli\u003eVerify terminal tightness before energizing the system.\u003c\/li\u003e\n\u003cli\u003eCheck cold junction compensation settings during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46254590099555,"sku":"TC-IXL061","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/TC-CCN013_3.png?v=1790143145","url":"https:\/\/precisemodule.com\/products\/honeywell-tc-ixl061-thermocouple-input-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}