{"product_id":"ics-triplex-t3310-digital-input-module-regent-i-o-safety-transceiver","title":"ICS Triplex T3310 Digital Input Module | Regent I\/O Safety Transceiver","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eICS Triplex T3310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDigital Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the TRIPLEX safety system family. Engineered for use in Safety Instrumented Systems (SIS), this module delivers robust monitoring of digital signals in high-integrity industrial environments, including oil \u0026amp; gas, chemical processing, and power generation. Its design emphasizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault tolerance, SIL 3 compliance, and high availability\u003c\/strong\u003e, making it suitable for critical applications that require continuous operation.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFunctionality\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT3310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the communication gateway between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRegent processor modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the field I\/O modules. Typically deployed in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etriplicated configuration\u003c\/strong\u003e, it ensures that the system remains operational even if a single transceiver fails. It manages digital input signals across the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafetybus\u003c\/strong\u003e, guaranteeing accurate transmission of sensor readings to processors and commands to actuators.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTriple Modular Redundancy (TMR)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFully supports triplicated system architecture, allowing any single module to fail without interrupting operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnables module replacement without powering down the system, maintaining continuous I\/O processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTÜV certified,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated for emergency shutdown (ESD) and fire \u0026amp; gas (F\u0026amp;G) systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront-panel LEDs provide real-time status of module activity and fault conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous monitoring of communication across all three triplicated modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation and Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical isolation safeguards logic circuits from surges or field-side failures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Data Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eManages bidirectional data transfer and validates chassis addresses to prevent misdirected commands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency Shutdown (ESD) systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFire \u0026amp; Gas (F\u0026amp;G) safety systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical digital signal monitoring in oil, gas, and chemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-integrity industrial automation requiring continuous fault-tolerant operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module \/ Regent I\/O Transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 or 16 configurable digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDry contact and 24V DC voltage signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 3W per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundancy (TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (-4°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade shock and vibration tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eICS Triplex Safetybus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL 3 \/ TÜV Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eGreen (Active), Red (Fault) LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e100 x 120 x 70 mm (3.94 x 4.72 x 2.76 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the T3310 module be replaced while the system is operational?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is hot-swappable, allowing replacement without shutting down the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of digital inputs does the module support?\u003c\/strong\u003e\u003cbr\u003eA: Supports both dry contact and 24V DC voltage signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many modules are recommended per I\/O chassis for redundancy?\u003c\/strong\u003e\u003cbr\u003eA: Typically, three modules are deployed in a triplicated configuration for full fault tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the T3310 suitable for SIL 3 safety applications?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is TÜV certified and compliant with SIL 3 standards.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ICS TRIPLEX","offers":[{"title":"Default Title","offer_id":44120812421219,"sku":"T3310","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ICST3310.jpg?v=1776310636","url":"https:\/\/precisemodule.com\/products\/ics-triplex-t3310-digital-input-module-regent-i-o-safety-transceiver","provider":"Precise Module Ltd.","version":"1.0","type":"link"}