{"product_id":"ics-triplex-t8110b-trusted™-tmr-processor-module-sil-3-controller","title":"ICS Triplex T8110B Trusted™ TMR Processor Module | SIL 3 Controller","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eICS Triplex T8110B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity, triple modular redundant (TMR) processor designed for safety-critical control systems. Serving as the central processing unit in Trusted™ safety systems, it ensures uninterrupted operation in applications where system failure could result in hazardous conditions. Its architecture and diagnostics are engineered for maximum reliability and compliance with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3 (IEC 61508)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTriple Modular Redundancy (TMR) Architecture\u003c\/strong\u003e\u003cbr\u003eThe processor features three independent processing channels operating in parallel, with a 2-out-of-3 voting mechanism to detect and isolate faults. This guarantees continued system operation even if a single module fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Processing\u003c\/strong\u003e\u003cbr\u003eThe T8110B provides tightly synchronized execution across all channels and rapid logic scanning, ensuring deterministic response times critical for Emergency Shutdown (ESD), Burner Management Systems (BMS), and Fire \u0026amp; Gas (F\u0026amp;G) applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Self-Diagnostics\u003c\/strong\u003e\u003cbr\u003eContinuous internal testing identifies and isolates errors while maintaining system availability. Faults trigger alarms, and the system continues in degraded mode until full redundancy is restored. Modules are fully hot-swappable to minimize downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003cbr\u003eSupports peer-to-peer communication with other Trusted™ controllers and integrates seamlessly via T8151B interface modules for Modbus or Ethernet\/IP connections to Distributed Control Systems (DCS) and HMIs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundant (TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Logic\u003c\/td\u003e\n\u003ctd\u003e2-out-of-3 voting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e20–32 V DC (System Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Clock\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eDRAM 16 MB EDO 60 ns, EPROM 512 kB, FLASH 2 MB, NVRAM 128 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetained Variable Storage\u003c\/td\u003e\n\u003ctd\u003eBooleans 1 byte, Analogues 4 bytes, Timers 5 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Buffer\u003c\/td\u003e\n\u003ctd\u003e1000 events, transferable to 4000-event CI buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIVO Interface\u003c\/td\u003e\n\u003ctd\u003eTriple redundant Inter-Module Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32–140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C (-13–158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e266 mm H × 93 mm W × 303 mm D (10.5 × 3.6 × 12.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.94 kg (6.48 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003eHot-swappable in live system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEmergency Shutdown (ESD)\u003c\/strong\u003e\u003cbr\u003eEnsures rapid and reliable shutdown of oil, gas, and chemical processes in hazardous conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFire and Gas (F\u0026amp;G) Systems\u003c\/strong\u003e\u003cbr\u003eMonitors sensor networks and activates suppression systems when thresholds are exceeded.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTurbomachinery Overspeed Protection\u003c\/strong\u003e\u003cbr\u003eProvides critical control for large turbines, safeguarding against mechanical or process failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBurner Management Systems (BMS)\u003c\/strong\u003e\u003cbr\u003eControls safe startup, operation, and shutdown of industrial boilers and furnaces.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module operate if one processor slice fails?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the 2oo3 voting logic allows the system to run safely in degraded mode while maintaining core functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module compatible with existing T8100 chassis systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the T8110B is fully compatible and hot-swappable within T8100 system backplanes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What kind of memory does it use for program storage?\u003c\/strong\u003e\u003cbr\u003eA: It uses a combination of DRAM, EPROM, FLASH, and NVRAM for program and retained variable storage.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ICS TRIPLEX","offers":[{"title":"Default Title","offer_id":44135941111907,"sku":"T8110B","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ICST8110B.jpg?v=1776928000","url":"https:\/\/precisemodule.com\/products\/ics-triplex-t8110b-trusted%e2%84%a2-tmr-processor-module-sil-3-controller","provider":"Precise Module Ltd.","version":"1.0","type":"link"}