{"product_id":"molex-sst-sr4-clx-rll-remote-i-o-link-module-allen-bradley-controllogix-honeywell-i-o-integration","title":"Molex SST-SR4-CLX-RLL | Remote I\/O Link Module | Allen-Bradley ControlLogix | Honeywell I\/O Integration","description":"\u003ch3\u003eProduct Description:\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eMolex SST-SR4-CLX-RLL\u003c\/span\u003e is a \u003cspan\u003eRemote I\/O Link (RIO) communication module\u003c\/span\u003e designed to integrate \u003cspan\u003eHoneywell I\/O\u003c\/span\u003e systems with \u003cspan\u003eAllen-Bradley ControlLogix\u003c\/span\u003e controllers, providing a seamless connection for \u003cspan\u003elegacy Honeywell TDC 3000\u003c\/span\u003e or \u003cspan\u003ePlantScape I\/O\u003c\/span\u003e equipment. This high-performance gateway enables modern ControlLogix PLCs to interface with older Honeywell hardware, allowing for a smooth migration and continued use of existing field wiring and I\/O racks during plant upgrades.\u003c\/p\u003e\n\u003cp\u003eThe \u003cspan\u003eSST-SR4-CLX-RLL\u003c\/span\u003e module, which is a \u003cspan\u003esingle-slot solution\u003c\/span\u003e, installs directly into a standard \u003cspan\u003eControlLogix 1756 I\/O chassis\u003c\/span\u003e, eliminating the need for additional external power supplies or separate gateway devices. It handles the protocol and timing requirements of the Honeywell \u003cspan\u003eRemote I\/O Link\u003c\/span\u003e, presenting I\/O data to the \u003cspan\u003eControlLogix processor\u003c\/span\u003e as standard tags for efficient control and monitoring.\u003c\/p\u003e\n\u003ch4\u003eKey Features \u0026amp; Functions:\u003c\/h4\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeamless Integration for Legacy Systems\u003c\/span\u003e:\u003cbr\u003eThe \u003cspan\u003eSST-SR4-CLX-RLL\u003c\/span\u003e module supports phased migrations by allowing plant owners to retain existing \u003cspan\u003eHoneywell I\/O\u003c\/span\u003e racks while upgrading to \u003cspan\u003eAllen-Bradley ControlLogix\u003c\/span\u003e systems. This minimizes downtime and reduces installation costs, making it ideal for modernization projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlug-and-Play Installation\u003c\/span\u003e:\u003cbr\u003eRecognized as a \"Generic 1756 Module\" within \u003cspan\u003eRSLogix 5000\u003c\/span\u003e or \u003cspan\u003eStudio 5000\u003c\/span\u003e, the module requires minimal configuration. Using \u003cspan\u003eMolex Console Software\u003c\/span\u003e, users can easily map memory and I\/O addresses for the ControlLogix processor to communicate with the Honeywell I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-Speed Data Transfer\u003c\/span\u003e:\u003cbr\u003eThe module is designed for \u003cspan\u003ehigh-speed data throughput\u003c\/span\u003e and is capable of scanning multiple \u003cspan\u003eHoneywell I\/O racks\u003c\/span\u003e simultaneously. This ensures minimal latency for time-sensitive applications such as \u003cspan\u003ePID control loops\u003c\/span\u003e and \u003cspan\u003esafety interlocks\u003c\/span\u003e, which require rapid data exchanges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-Time Diagnostics\u003c\/span\u003e:\u003cbr\u003eThe \u003cspan\u003eSST-SR4-CLX-RLL\u003c\/span\u003e features a \u003cspan\u003efront-panel diagnostic LED\u003c\/span\u003e system that provides immediate feedback on the module's status:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCOMM\u003c\/span\u003e: Indicates active communication with the Honeywell link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSYS\u003c\/span\u003e: Displays the internal health of the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOK\u003c\/span\u003e: Shows that communication with the ControlLogix backplane is active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRobust and Reliable\u003c\/span\u003e:\u003cbr\u003eWith \u003cspan\u003e500 VDC isolation\u003c\/span\u003e between the network and backplane, the module offers strong protection against electrical noise, ensuring reliable operation in industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eTechnical Specifications:\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSST-SR4-CLX-RLL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePlatform Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \u003cspan\u003eControlLogix\u003c\/span\u003e (1756 Chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell Remote I\/O Link (RIO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell I\/O Link (Serial\/High Speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eDependent on Honeywell Link Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScan Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed logic execution (typically \u0026lt;10ms for full scan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5.1 VDC; 3 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnectors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 5-pin Phoenix-style plug (Network Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e500 VDC (Network to Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInstallation \u0026amp; Configuration:\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting\u003c\/span\u003e: The \u003cspan\u003eSST-SR4-CLX-RLL\u003c\/span\u003e installs into a single slot of the \u003cspan\u003eControlLogix 1756 Chassis\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCabling\u003c\/span\u003e: The module uses a \u003cspan\u003eshielded twisted-pair (STP)\u003c\/span\u003e cable to meet \u003cspan\u003eHoneywell I\/O Link\u003c\/span\u003e specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSoftware\u003c\/span\u003e: Configuration is managed through the \u003cspan\u003eMolex Console Software\u003c\/span\u003e, which facilitates memory mapping and address configuration for the I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAddressing\u003c\/span\u003e: The module supports a full range of \u003cspan\u003eHoneywell I\/O addresses\u003c\/span\u003e and can be configured as the \u003cspan\u003eMaster\u003c\/span\u003e device on the link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eMolex SST-SR4-CLX-RLL\u003c\/span\u003e is a vital tool for modernizing industrial control systems, enabling integration between \u003cspan\u003eAllen-Bradley ControlLogix\u003c\/span\u003e controllers and legacy \u003cspan\u003eHoneywell I\/O\u003c\/span\u003e equipment. Ideal applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy System Migration\u003c\/span\u003e: Replacing older Honeywell controllers with modern \u003cspan\u003eControlLogix\u003c\/span\u003e systems while retaining existing \u003cspan\u003eHoneywell I\/O\u003c\/span\u003e racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial Automation\u003c\/span\u003e: Enhancing communication between \u003cspan\u003ePLCs\u003c\/span\u003e and \u003cspan\u003efield devices\u003c\/span\u003e in high-speed, real-time applications such as \u003cspan\u003ePID control\u003c\/span\u003e and \u003cspan\u003esafety interlocks\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ):\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: What does the SST-SR4-CLX-RLL module do?\u003c\/span\u003e\u003cbr\u003eA: The \u003cspan\u003eSST-SR4-CLX-RLL\u003c\/span\u003e is a \u003cspan\u003eRemote I\/O Link (RIO)\u003c\/span\u003e communication module that allows \u003cspan\u003eAllen-Bradley ControlLogix\u003c\/span\u003e PLCs to communicate with \u003cspan\u003eHoneywell I\/O systems\u003c\/span\u003e, including legacy equipment such as \u003cspan\u003eTDC 3000\u003c\/span\u003e and \u003cspan\u003ePlantScape I\/O\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can I use the SST-SR4-CLX-RLL for phased migration of Honeywell systems?\u003c\/span\u003e\u003cbr\u003eA: Yes, this module is specifically designed to facilitate \u003cspan\u003ephased migrations\u003c\/span\u003e, allowing you to replace older \u003cspan\u003eHoneywell controllers\u003c\/span\u003e with \u003cspan\u003eAllen-Bradley ControlLogix\u003c\/span\u003e without the need to replace existing \u003cspan\u003eHoneywell I\/O racks\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How do I configure the SST-SR4-CLX-RLL?\u003c\/span\u003e\u003cbr\u003eA: Configuration is done through \u003cspan\u003eMolex Console Software\u003c\/span\u003e, which simplifies the process of memory mapping and configuring the \u003cspan\u003eHoneywell I\/O addresses\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How does the SST-SR4-CLX-RLL improve system reliability?\u003c\/span\u003e\u003cbr\u003eA: The module offers \u003cspan\u003e500 VDC isolation\u003c\/span\u003e between the network and backplane, ensuring reliable operation and protection from electrical noise common in industrial environments.\u003c\/p\u003e","brand":"MOLEX","offers":[{"title":"Default Title","offer_id":44091773714531,"sku":"SST-SR4-CLX-RLL","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/SST-SR4-CLX-RLL.jpg?v=1774924188","url":"https:\/\/precisemodule.com\/products\/molex-sst-sr4-clx-rll-remote-i-o-link-module-allen-bradley-controllogix-honeywell-i-o-integration","provider":"Precise Module Ltd.","version":"1.0","type":"link"}