{"product_id":"schneider-electric-fbm201-p0916rb-8-channel-analog-input-module","title":"Schneider Electric FBM201 P0916RB 8-Channel Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM201 (P0916RB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Schneider Electric is a precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-channel analog input Fieldbus Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the Foxboro I\/A Series and EcoStruxure Foxboro Distributed Control System. It converts 0–20 mA signals from field transmitters into digital values for the Field Control Processor (FCP), ensuring reliable, high-accuracy process control in demanding industrial environments such as chemical plants, refineries, and power generation facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEight Fully Isolated Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel is galvanically isolated to prevent common-mode interference and electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReplace modules without powering down the system, enabling uninterrupted operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact DIN Rail Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with standard 200 Series baseplates for streamlined installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-Monitoring Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuously checks module health and signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan be paired with compatible baseplates for redundant operation where critical uptime is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ω nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation \u0026amp; Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Ground Isolation\u003c\/td\u003e\n\u003ctd\u003e600 V AC for 60 s \/ 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 dB at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eSurge and short-circuit resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Mbps HDLC fieldbus to FCP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for high-speed control loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental \u0026amp; Physical\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C (-4°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm H × 45 mm W × 114 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Termination\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0916RB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires a compatible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTermination Assembly (TA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto connect field wiring. Termination assemblies provide secure connections for 4–20 mA loops and may include fuses or signal conditioning modules. Ensure field transmitters are powered correctly; 2-wire devices require loop power supplied either by the module or an external source.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Measurement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure, temperature, or level sensing from analog transmitters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInput signals from flow meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTank and Vessel Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuous level measurement using analog probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eMaintenance \u0026amp; Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFront Panel Indicators:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFBM OK (Green\/Red):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModule health status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication (Yellow):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eData activity on fieldbus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure P0916RB matches the installed baseplate type (RH924 series).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ \u0026amp; Comparison\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can P0916RB operate in redundant configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, pairing with compatible baseplates enables redundant operation for critical processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does FBM201 differ from older FBM modules?\u003c\/strong\u003e\u003cbr\u003eA: FBM201 provides higher accuracy, full isolation, and faster update rates than previous 200 Series analog input modules.\u003c\/p\u003e","brand":"FOXBORO","offers":[{"title":"Default Title","offer_id":44114252234851,"sku":"P0916RB","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/FOXBOROP0916RB.jpg?v=1776073338","url":"https:\/\/precisemodule.com\/products\/schneider-electric-fbm201-p0916rb-8-channel-analog-input-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}