{"product_id":"triconex-4000094-110n-nuclear-qualified-external-termination-panel-etp-v10-safety-system","title":"Triconex 4000094-110N | Nuclear Qualified External Termination Panel (ETP) | V10 Safety System","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNuclear-qualified External Termination Panel (ETP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned specifically for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTricon V10 Triple Modular Redundant (TMR) safety systems\u003c\/strong\u003e. It acts as an interface between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield wiring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(sensors and actuators) and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTricon I\/O modules\u003c\/strong\u003e. With its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseismic rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand environmental ruggedness, this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eETP module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to meet the stringent standards required for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety-critical applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enuclear power plants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density analog or digital input termination panel\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimplifies field wiring while maintaining robust electrical connections in harsh industrial environments. It ensures that signals from field devices are properly conditioned and passed to the I\/O modules in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTricon chassis\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features \u0026amp; Functions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoften incorporates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision shunt resistors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., 250-ohm) for converting standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efield signals into the required\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1-5 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal range for the Tricon I\/O modules. This conditioning ensures compatibility and reliable data transmission for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTriple Redundant Signal Path\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIn alignment with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTricon system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ephilosophy, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eETP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that each field signal is split into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree isolated branches\u003c\/strong\u003e, creating a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant path\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the I\/O module’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etriplicated analog-to-digital converters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(A\/D). This process is essential for achieving\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand enhancing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault tolerance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNuclear Qualification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enuclear industry\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseismic-rated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCategory I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eevents. It maintains operational integrity during a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDesign Basis Earthquake (DBE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is constructed from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflame-retardant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ematerials, making it suitable for high-radiation and extreme environmental conditions. Additionally, it undergoes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCommercial Grade Dedication (CGD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1E safety-related equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEase of Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimplifies maintenance with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swappable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O modules. Since the field wiring remains connected to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eETP\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be replaced without disturbing the field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe module also features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediagnostic test points\u003c\/strong\u003e, allowing maintenance technicians to check the field signals without disconnecting or disturbing the connections, ensuring minimal downtime during routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Field Wiring Termination\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecomes with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompression screw terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-24 AWG\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewire, ensuring secure connections for a wide range of field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Nuclear Qualified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal Termination Panel (ETP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTricon V10 High-Density I\/O Modules (e.g., 3721N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Input Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch Rack or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompression screw terminals (12-24 AWG wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeismic Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory I (Nuclear Qualified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eTypical System Configuration\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Device (e.g., Pressure Transmitter)\u003c\/strong\u003e: Sends 4-20 mA signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eETP (4000094-110N)\u003c\/strong\u003e: Receives and conditions the signal, ensuring it is suitable for the I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Cable\u003c\/strong\u003e: Heavy-duty, shielded cable connects the ETP to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTricon chassis\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module (e.g., 3721N)\u003c\/strong\u003e: Processes the conditioned signal for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTricon main processors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enuclear power plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto interface between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield devices\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(such as sensors and actuators) and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTricon V10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety system. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enuclear qualification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that it can operate reliably in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety-critical systems\u003c\/strong\u003e, even under harsh environmental and seismic conditions.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does the\u003cspan\u003e \u003c\/span\u003e4000094-110N\u003cspan\u003e \u003c\/span\u003eensure signal integrity in the system?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esplits each input signal into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree isolated branches\u003c\/strong\u003e. This design works with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTricon system’s triplicated A\/D converters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure redundancy and prevent errors, providing maximum system reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the\u003cspan\u003e \u003c\/span\u003e4000094-110N\u003cspan\u003e \u003c\/span\u003ebe used in non-nuclear environments?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNuclear-qualified\u003c\/strong\u003e, its ruggedized design and high-quality components make it suitable for use in various industrial environments where reliability and fault tolerance are crucial.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the\u003cspan\u003e \u003c\/span\u003e4000094-110N\u003cspan\u003e \u003c\/span\u003eeasy to maintain?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4000094-110N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swappable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediagnostic test points\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor easy maintenance and troubleshooting, reducing downtime during routine inspections or repairs.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":44089715621987,"sku":"4000094-110N","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/4000094-110N.jpg?v=1774853762","url":"https:\/\/precisemodule.com\/products\/triconex-4000094-110n-nuclear-qualified-external-termination-panel-etp-v10-safety-system","provider":"Precise Module Ltd.","version":"1.0","type":"link"}