{"product_id":"yokogawa-adv551-p63-digital-output-module-32-channel-centum-vp","title":"Yokogawa ADV551-P63 Digital Output Module | 32-Channel | CENTUM VP","description":"\u003ch4\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan\u003eYokogawa ANT502-5E\u003c\/span\u003e is a high-performance \u003cspan\u003eOptical Fiber Performance Expansion Unit\u003c\/span\u003e (also known as an \u003cspan\u003eOptical Fiber Bus Repeater\u003c\/span\u003e) designed to extend the communication distance between the \u003cspan\u003eField Control Station (FCS)\u003c\/span\u003e and the \u003cspan\u003eRemote I\/O Node Units\u003c\/span\u003e in the \u003cspan\u003eYokogawa CENTUM VP Distributed Control System (DCS)\u003c\/span\u003e. It is used in applications where the distance between I\/O nodes exceeds the limits of conventional copper wiring (ESB cables). The \u003cspan\u003eANT502\u003c\/span\u003e acts as a \u003cspan\u003eslave-side repeater\u003c\/span\u003e, receiving optical signals from a master-side module (typically the \u003cspan\u003eANT401\u003c\/span\u003e) and converting them into electrical signals for the local I\/O rack.\u003c\/p\u003e\n\u003cp\u003eThe \u003cspan\u003e-5E\u003c\/span\u003e suffix indicates a specific hardware revision, featuring \u003cspan\u003edual-redundant optical ports\u003c\/span\u003e and \u003cspan\u003estandard environmental protection\u003c\/span\u003e, ensuring reliability and continuous communication in large-scale industrial plants.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModel\u003c\/span\u003e: \u003cspan\u003eYokogawa ANT502-5E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan\u003eOptical Fiber Performance Expansion Unit\u003c\/span\u003e, \u003cspan\u003eSlave-Side Repeater\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e: Designed for \u003cspan\u003eYokogawa CENTUM VP\u003c\/span\u003e and \u003cspan\u003eCENTUM CS 3000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e: Dual-redundant configuration for high availability, offering \u003cspan\u003ebumpless switchover\u003c\/span\u003e in case of a failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistance Extension\u003c\/span\u003e: Extends communication up to \u003cspan\u003e2 km\u003c\/span\u003e (1.24 miles) between master (ANT401) and slave (ANT502)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignal Conversion\u003c\/span\u003e: Converts optical fiber signals to electrical signals for local I\/O racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eOptical Fiber\u003c\/span\u003e (Multi-mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e2 Ports\u003c\/span\u003e (supports \u003cspan\u003eDual-Redundant\u003c\/span\u003e configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e2 km\u003c\/span\u003e (1.24 miles) between \u003cspan\u003eMaster\u003c\/span\u003e and \u003cspan\u003eSlave\u003c\/span\u003e units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBus Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eExtension Serial Bus (ESB)\u003c\/span\u003e over fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eLC-type\u003c\/span\u003e fiber optic connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Platform Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eYokogawa CENTUM VP\u003c\/span\u003e and \u003cspan\u003eCENTUM CS 3000\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNode Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eInstalled in \u003cspan\u003eANB10\u003c\/span\u003e (Interface Building Block) or \u003cspan\u003eANB11\u003c\/span\u003e (Node Unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e24 V DC\u003c\/span\u003e (via node unit backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0.5 A\u003c\/span\u003e (at 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeat Dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e~ 12 W\u003c\/span\u003e (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLong-Distance Integration\u003c\/span\u003e: Enables \u003cspan\u003eremote I\/O racks\u003c\/span\u003e to be placed in \u003cspan\u003esatellite instrument houses (SIH)\u003c\/span\u003e or other distant locations, maintaining high-speed communication and control between distributed nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical Isolation\u003c\/span\u003e: Optical fiber provides \u003cspan\u003ecomplete galvanic isolation\u003c\/span\u003e, preventing the DCS from being affected by lightning strikes, ground potential differences, and other electrical interferences that can occur between buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh Availability\u003c\/span\u003e: With \u003cspan\u003edual-redundant optical ports\u003c\/span\u003e, the ANT502 ensures continuous communication. If one fiber optic link fails (e.g., due to a cable cut), the system automatically switches to the secondary path, preventing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-Time Diagnostics\u003c\/span\u003e: Front-panel \u003cspan\u003eLED indicators\u003c\/span\u003e display real-time status:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSTATUS\u003c\/span\u003e: Indicates overall health of the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSND\/RCV\u003c\/span\u003e: Displays activity on the optical communication link (Transmit\/Receive).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSYNC\u003c\/span\u003e: Displays synchronization status with the master module (ANT401).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003ePhysical \u0026amp; Environmental Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eOccupies a \u003cspan\u003ededicated slot\u003c\/span\u003e in the \u003cspan\u003eI\/O Node Unit\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e (Standard industrial range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e5% to 95% RH\u003c\/span\u003e (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eG3-level conformal coating\u003c\/span\u003e for protection against \u003cspan\u003ecorrosive atmospheric gases\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44092731916387,"sku":"ADV551-P63","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ADV551-P63-1.jpg?v=1774950757","url":"https:\/\/precisemodule.com\/products\/yokogawa-adv551-p63-digital-output-module-32-channel-centum-vp","provider":"Precise Module Ltd.","version":"1.0","type":"link"}