{"product_id":"yokogawa-agp813-s10-protection-module-high-speed-turbomachinery-i-o","title":"Yokogawa AGP813-S10 Protection Module | High-Speed Turbomachinery I\/O","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AGP813-S10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed protection module engineered for turbomachinery and critical rotating equipment within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems. It executes rapid signal processing with robust electrical isolation, ensuring reliable performance for overspeed trips, emergency interlocks, and other safety-critical operations.\u003c\/p\u003e\n\u003cp\u003eDesigned for harsh industrial conditions such as chemical plants, refineries, and power generation facilities, the AGP813-S10 safeguards equipment from catastrophic failure while maintaining precise, millisecond-level response.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAGP813-S10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Speed Protection Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 high-speed, 6 basic cycle (isolated), 1–5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 basic cycle (isolated), 10 kΩ impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnetic Pickup Inputs (MPU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5–150 Vpp, 50 Hz–25 kHz, ±0.05% accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActive Pickup Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 1 \u0026amp; Type 2, 0.04 Hz–2 kHz, 50% ±5% duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs (SoE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 high-speed, 8 basic cycle (isolated), 24 V DC sink type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 high-speed, 8 basic cycle (isolated), current sinking, max 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScan Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms (high-speed), 10 ms (basic cycle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e144 × 100 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute between system and field, and between I\/O types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports up to 100 gates of user-defined logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandby dual-redundant configuration compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Logic Execution\u003c\/strong\u003e\u003cbr\u003eThe module processes protection logic locally, achieving reaction times as low as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 ms\u003c\/strong\u003e, independent of the main Field Control Station (FCS), essential for preventing overspeed or mechanical damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Isolation\u003c\/strong\u003e\u003cbr\u003eWithstand voltages up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e500 V AC\u003c\/strong\u003e, separating system electronics from field signals to prevent faults or electrical noise from affecting the DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Sequence of Events (SoE)\u003c\/strong\u003e\u003cbr\u003eRecords the precise millisecond an event occurs, allowing engineers to identify the first input that triggered a trip for post-event diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Configuration\u003c\/strong\u003e\u003cbr\u003eProtection logic is defined through a dedicated Logic Builder tool, enabling simulation and validation on a PC before deployment, ensuring safe and reliable operation from initial startup.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbomachinery overspeed protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge motor and compressor safety control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower load imbalance detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency interlock and safety shutdown systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AGP813-S10 be used with both CENTUM VP and CENTUM CS 3000 systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is fully compatible with both DCS platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it require an external power source?\u003c\/strong\u003e\u003cbr\u003eA: No, it operates using a 5 V DC supply from the control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How fast does the module respond to high-speed events?\u003c\/strong\u003e\u003cbr\u003eA: It can execute protection logic in as little as 5 milliseconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module handle redundant configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports standby dual-redundant setups for critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of inputs are supported?\u003c\/strong\u003e\u003cbr\u003eA: Magnetic pickups, active pickups, voltage inputs, pulse inputs, and high-speed digital signals.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44119024402531,"sku":"AGP813-S10","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/AGP813-S10.jpg?v=1774919044","url":"https:\/\/precisemodule.com\/products\/yokogawa-agp813-s10-protection-module-high-speed-turbomachinery-i-o","provider":"Precise Module Ltd.","version":"1.0","type":"link"}