{"product_id":"yokogawa-alr111-s00-serial-communication-module-centum-vp-cs-3000","title":"Yokogawa ALR111-S00 Serial Communication Module CENTUM VP\/CS 3000","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ALR111-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust RS-232C serial communication module designed for integration with CENTUM VP and CENTUM CS 3000 Distributed Control Systems. This module enables precise, high-speed data exchange between Field Control Stations (FCS) and peripheral devices such as PLCs, chromatographs, or digital weighing scales. Its standard configuration does not include explosion-proof features or special conformal coating beyond industrial-grade requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel \/ Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eALR111-S00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eRS-232C (D-sub 9-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNumber of Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e2 independent ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e300 bps – 115,200 bps (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eUp to 15 meters (standard RS-232C limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e7 or 8 bits per character\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eParity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eNone \/ Even \/ Odd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eStop Bits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 or 2 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eStart-stop method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eTransmission Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHalf-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eLag Time After Transmission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSupports dual-redundant configuration in adjacent slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.5 A (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMounting Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eANB10, ANB11, ANR10, AFF50, AFV10, AFV30, AFV40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCabling Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eAKB131\/132\/133\/134, or shielded 3-pair AKB161\/162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEfficiently manages large volumes of data without impacting control loop performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Builders allow mapping of external device data (e.g., Modbus) to FCS functional blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReplaceable under maintenance conditions without shutting down the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel indicators provide immediate status on activity, health, and errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eALR111-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for industrial environments where reliable point-to-point serial communication is required, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess monitoring with PLCs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData collection from analytical instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with weighing and batching equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComparison with ALR121\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhile\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eALR111-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports RS-232C for point-to-point connections, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eALR121\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant offers RS-422\/RS-485 for longer distances (up to 1200 meters) and multipoint networks, making it suitable for distributed sensor systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module handle distances beyond 15 meters?\u003c\/strong\u003e\u003cbr\u003eA: RS-232C is limited to 15 meters; use RS-422\/RS-485 (ALR121) for longer runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eA: Yes, replacement is possible under specified maintenance procedures without powering down the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protocols are supported?\u003c\/strong\u003e\u003cbr\u003eA: Both standard protocols and user-defined protocols via ALRECU software.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44120559878243,"sku":"ALR111-S00","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/YOKOGAWAALR111-S00-3.jpg?v=1776301547","url":"https:\/\/precisemodule.com\/products\/yokogawa-alr111-s00-serial-communication-module-centum-vp-cs-3000","provider":"Precise Module Ltd.","version":"1.0","type":"link"}