Honeywell
📢 100% genuine, extensive in-stock inventory, fast shipping!
Honeywell 51202789-900 Link Interface Cable
Honeywell 51202789-900 Link Interface Cable
Manufacturer: Honeywell
-
Product No.: 51202789-900
Condition:in Stock
Product Type: Link Interface Cable
-
Product Origin: USA
Payment:T/T, Western Union
-
Weight: 200g
Shipping port: Shanghai/Yiwu/Shenzhen
Warranty: 12 months
Share
Honeywell 51202789-900 Link Interface Cable
The Honeywell 51202789-900, also cataloged as the 51202789 Link Interface Cable, operates as a shielded extender assembly for I/O communication between Honeywell controllers and MOXA interface devices in distributed control system (DCS) environments.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 51202789-900 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.2 kg (0.44 lbs) |
| Dimensions | Length 1 m (approx. 39 in) |
| Operating Temp | -40 to +85 deg C (structural exposure up to +150 deg C) |
| Storage Temp | Not specified |
| Relative Humidity | Up to 95%, non-condensing |
| Power Consumption | Passive cable |
| Core Performance | Shielded RJ45 / Honeywell-specific headers, copper alloy conductors with Teflon insulation |
FOUNDATION Fieldbus / Profibus PA Connectivity
The cable is optimized for Honeywell Experion PKS (C300 controllers) and Series C I/O modules, while maintaining backward compatibility with TDC 3000 systems. Full EMI/RFI shielding ensures stable communication in high-noise environments. Channel-to-channel isolation is preserved through conductor geometry, supporting FOUNDATION Fieldbus and Profibus PA connectivity standards for extended cabinet layouts.
Frequently Asked Questions
Q: Can the 51202789-900 be used with non-Honeywell controllers? A: No, it is factory-terminated with Honeywell-specific headers and designed for Experion PKS and Series C systems.
Q: What is the maximum current rating for this cable? A: The cable supports up to 10 A continuous current within its rated voltage limits.
Q: How should shielding be terminated during installation? A: Shielding must be grounded at the controller end only to prevent ground loop currents.
Field Installation Guidelines
- Install into cabinet routing with full connector engagement on RJ45 and Honeywell-specific headers.
- Route separately from high-voltage conductors to minimize EMI/RFI interference.
- Ground shielding at the controller termination point only.
- Verify continuity and insulation integrity before commissioning.
- Avoid mechanical stress or bending beyond manufacturer specifications.
Hot Tags :

- Choosing a selection results in a full page refresh.
- Opens in a new window.