The Honeywell 10310/1/1 serves as the primary 10310/1/1 Earth Leakage Detector utilized to execute earth fault monitoring and leakage detection across industrial control and power distribution platforms. The device monitors leakage conditions, provides relay-based output switching, and supports reset control functions through dedicated field interfaces.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 10310/1/1 |
| Brand | Honeywell |
| Origin | Not specified |
| Product Type | Earth Leakage Detector |
| Approvals | CE |
| Supply Voltage | 24 VDC (30 VDC maximum) |
| Supply Current | 60 mA maximum |
| Reset Input Voltage | 18-70 VDC |
| Reset Input Current | 1.1 mA at 24 VDC |
| Maximum Output Voltage | 115 VDC |
| Maximum Output Current | 2 A |
| Operating Temp | -55 deg C to +65 deg C |
| Dimensions | 70 mm x 45 mm x 100 mm |
| Weight | 3 kg |
| Shipping Weight | 4 kg |
| Detection Function | Earth leakage monitoring |
| Output Type | Relay output interface |
Channel-to-Channel Isolation and Control Interface Integrity
The 10310/1/1 Earth Leakage Detector is designed to identify leakage conditions within industrial electrical systems and provide corresponding output status signals. The detector interfaces with external alarm circuits, protection devices, and control equipment through dedicated output contacts.
Electrical separation between detection circuitry and external control connections helps maintain stable operation in environments where switching transients and field-induced disturbances may be present. Proper wiring practices and grounding arrangements contribute to consistent fault indication performance.
Frequently Asked Questions
Q: What supply voltage is required for the 10310/1/1?
A: The detector operates from a nominal 24 VDC supply and accepts up to 30 VDC maximum.
Q: What output load can the module switch?
A: The output is rated for up to 115 VDC and 2 A maximum load current.
Q: Is an external reset signal supported?
A: Yes. The reset input accepts 18-70 VDC signals and draws approximately 1.1 mA at 24 VDC.
Field Installation Guidelines
-
Mount the detector in an appropriate control cabinet location.
-
Verify supply polarity before energization.
-
Separate detection wiring from power conductors.
-
Confirm reset input voltage compatibility.
-
Check output load ratings before connection.
-
Verify grounding continuity during commissioning.