Honeywell
📢 100% genuine, extensive in-stock inventory, fast shipping!
Honeywell 05701-A-0302 Single Channel Control Card
Honeywell 05701-A-0302 Single Channel Control Card
Manufacturer: Honeywell
-
Product No.: 05701-A-0302
Condition:in Stock
Product Type: Single Channel Control Card
-
Product Origin: USA
Payment:T/T, Western Union
-
Weight: 165g
Shipping port: Shanghai/Yiwu/Shenzhen
Warranty: 12 months
Share
Honeywell 05701-A-0302 Single Channel Control Card
The Honeywell 05701‑A‑0302, also cataloged as the 05701‑A‑0302 single‑channel control card, operates as a catalytic measurement and alarm‑processing module within Honeywell fixed‑gas detection and control assemblies. It provides direct electrical execution for sensor excitation, bar‑graph indication, and multi‑level alarm signaling.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 05701‑A‑0302 |
| Brand | Honeywell |
| Origin | Honeywell industrial gas detection platforms |
| Weight | 0.165 kg (1.5 kg shipping) |
| Dimensions | 17 cm × 2.5 cm × 11.2 cm |
| Operating Temp | Standard industrial ambient range |
| Power Consumption | 3.75 W typical (including catalytic sensor) |
| Power Supply | 18 V to 32 V DC |
| Module Type | Single‑channel catalytic control card |
| Display | 25‑segment analog bar graph + 4‑character digital display |
| Alarm Indicators | A1, A2, A3 gas alarms; fault; inhibit |
| Design Notes | Independent channel operation; card replacement without disturbing wiring |
Channel‑to‑Channel Isolation in Honeywell Process‑Control Cards
Honeywell control cards maintain deterministic separation between measurement, alarm, and fault‑indication circuits. This prevents cross‑talk between catalytic sensor excitation and bar‑graph display drivers, ensuring stable loop behavior. The isolation approach aligns with Honeywell’s broader process‑control design practices, including predictable boundaries used in 4‑20 mA HART loop protocol and Fieldbus/Profibus gateway modules.
Frequently Asked Questions
Q: Can the card be replaced while the system remains energized? A: No. Replacement must be performed during a controlled shutdown to avoid alarm‑loop disturbance.
Q: Does the card support independent operation per channel? A: Yes. Each card handles one catalytic channel and can be replaced without affecting adjacent modules.
Q: Are the alarm indicators driven directly from sensor input? A: Alarm thresholds are processed on the card, with dedicated outputs for A1, A2, A3, fault, and inhibit states.
Field Installation Guidelines
- Seat the card fully into the backplane to ensure stable sensor excitation and alarm signaling.
- Maintain correct wiring orientation to avoid mis‑routing of alarm outputs.
- Keep sensor cabling segregated from high‑voltage conductors to reduce interference.
- Verify bar‑graph and digital display operation after installation.
- Confirm alarm thresholds using system‑level calibration routines.
Hot Tags :

- Choosing a selection results in a full page refresh.
- Opens in a new window.