Skip to product information
1 of 3

Honeywell

📢 100% genuine, extensive in-stock inventory, fast shipping!

Honeywell 51202329-111 Violet Drop Cable

Honeywell 51202329-111 Violet Drop Cable

  • Manufacturer: Honeywell

  • Product No.: 51202329-111

  • Condition:in Stock

  • Product Type: Violet Drop Cable

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1000g

  • Shipping port: Shanghai/Yiwu/Shenzhen

  • Warranty: 12 months

Honeywell 51202329-111 Violet Drop Cable

The Honeywell 51202329-111, also cataloged as the 51202329 Series C I/O Link drop cable, operates as Cable B for structured signal distribution between C300 controllers and I/O Termination Assemblies in Experion PKS systems.

Part Number Breakdown

  • Model (51202329): Series C I/O Link drop cable
  • Cable Classification: Cable B
  • Jacket Color: Violet (standard Honeywell I/O Link coding)
  • Label Identification: Green label (Cable B differentiation)
  • Number of Drops: 6 module connections
  • Pitch Spacing: 6 in (152 mm) center-to-center between drops

Hardware Specifications

Parameter Specification
Model 51202329-111
Brand Honeywell
Origin USA
Weight Not specified
Dimensions 6 in (152 mm) pitch spacing; 6 module drops
Operating Temp Matches standard industrial cabinet enclosure limits
Power Consumption Passive cable
Core Performance Violet jacket; green label identification; CE certified; redundant bidirectional communication

Channel-to-Channel Isolation and Redundant Connectivity

The cable enforces channel-to-channel isolation across redundant Series C networks. Six discrete drops provide structured connectivity to I/O modules, while violet jacket coloration ensures clear identification in dense wiring environments. Green marking labels distinguish Cable B from Cable A, preventing misrouting in dual-channel redundancy. Shield continuity and grounding practices suppress induced noise during installation.

Frequently Asked Questions

Q: Can the 51202329-111 cable be used interchangeably with Cable A? A: No. It is designated as Cable B; redundant operation requires pairing with Cable A.

Q: How are redundant cables identified in the field? A: Jacket color and green marking labels provide clear distinction between Cable B and Cable A.

Q: What is the recommended installation spacing? A: Maintain the 6 in (152 mm) pitch spacing between drops to preserve mechanical integrity and alignment.

Field Installation Guidelines

  • Assign Cable B correctly in redundant channel mapping; use green labels for identification.
  • Route drop cables separately from high-voltage conductors to minimize EMI.
  • Ground shielding at the controller end only to prevent ground loop currents.
  • Verify continuity and drop assignment during commissioning with loop test equipment.
  • Maintain bend radius within manufacturer specifications to protect conductor insulation.
View full details