Skip to product information
1 of 3

Honeywell

📢 100% genuine, extensive in-stock inventory, fast shipping!

Honeywell 51304481-100 Low Level Analog Input Module

Honeywell 51304481-100 Low Level Analog Input Module

  • Manufacturer: Honeywell

  • Product No.: 51304481-100

  • Condition:in Stock

  • Product Type: Analog Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 450g

  • Shipping port: Shanghai/Yiwu/Shenzhen

  • Warranty: 12 months

Honeywell 51304481-100 Low Level Analog Input Module

The Honeywell 51304481-100, also cataloged as the 51304481 Low Level Analog Input Module, operates as a dedicated hardware component for low-level process signal acquisition within Honeywell UCN-based distributed control systems. The module accepts millivolt and thermocouple inputs through differential measurement circuits, providing high-resolution analog conversion, cold junction compensation, and redundant I/O processing capabilities.

Hardware Specifications

Parameter Specification
Model 51304481-100
Brand Honeywell
Product Type Low Level Analog Input Module
Model Identifier MU-PAIL02
Channel Count 8 differential input channels
Signal Compatibility Millivolt (mV), Thermocouple
A/D Resolution 16-bit
Signal Compensation Integrated cold junction compensation
Network Integration Honeywell UCN (Universal Control Network)
Redundancy Support Redundant IOP configuration supported
Input Architecture Differential inputs
Power Supply 24 VDC
Weight Approximately 0.45 kg
Origin United States

Cold Junction Compensation and Low-Level Signal Measurement

The 51304481-100 is optimized for acquisition of low-amplitude field signals where measurement stability and thermal compensation are required. Integrated cold junction compensation automatically corrects thermocouple reference junction temperature variations, improving measurement accuracy at the I/O termination point.

The differential input architecture assists in minimizing common-mode noise pickup from field wiring. This configuration is particularly beneficial when measuring low-energy thermocouple and millivolt signals that may be affected by electrical interference present in industrial environments.

Frequently Asked Questions

Q: What signal types can be connected to the 51304481-100?
A: The module is designed for millivolt and thermocouple signal inputs and is intended for low-level analog measurement applications.

Q: Does the module provide thermocouple temperature compensation?
A: Yes. The module incorporates integrated cold junction compensation for thermocouple measurement accuracy.

Q: Can the module participate in redundant system architectures?
A: Yes. The module supports redundant IOP configurations, allowing paired processors to connect to the same field termination assembly through independent communication paths.

Field Installation Guidelines

  • Verify thermocouple type and channel configuration prior to wiring field devices.

  • Use matching thermocouple extension cable to maintain measurement accuracy.

  • Route low-level signal wiring separately from motor power, relay, and high-current conductors.

  • Maintain proper shield grounding practices according to plant instrumentation standards.

  • Avoid unnecessary junctions or splices in thermocouple circuits.

  • Confirm polarity on thermocouple and millivolt inputs before commissioning.

  • For redundant installations, verify communication paths and field termination connections for both IOP channels.

  • Perform input simulation and loop verification after installation to confirm channel operation and scaling.

View full details