Honeywell 51400764-100 Dual Fan Module
The Honeywell 51400764-100, also cataloged as the 51400764 Dual Fan Module, operates as a dedicated hardware component for forced-air cooling across Honeywell 5-slot rack and chassis bays, including DNCFA and TDC 3000 node electronics.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 51400764-100 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 2.01 lbs (0.91 kg) |
| Dimensions | 16.3 cm × 8.2 cm × 4.1 cm (6.42 in × 3.23 in × 1.61 in) |
| Operating Temp | 0 deg C to 60 deg C |
| Storage Temp | -40 deg C to +85 deg C |
| Voltage Rating | 24 VDC nominal |
| Current Draw | Not specified |
| Power Consumption | Not specified |
| Component Type | Dual-fan cooling assembly |
| Airflow Capacity | ~100 CFM total (~50 CFM per fan) |
| Diagnostics | Integrated front-facing red LED status indicator |
| Chassis Compatibility | Honeywell 5-slot rack/chassis bays |
| HS Code | 841459 (Industrial Fans/Ventilation equipment) |
4-20 mA HART Loop Protocol and Channel Isolation
Although primarily a cooling assembly, integration with Honeywell chassis systems often involves modules utilizing 4-20 mA HART loop protocol. The fan module’s diagnostic LED can be wired into monitoring channels, ensuring channel-to-channel isolation and preventing electrical noise propagation. This design supports stable operation in dense control environments where thermal degradation could impact signal fidelity.
Frequently Asked Questions (FAQ)
Q: Can the 51400764-100 fan module be hot-swapped? A: No, cabinet power must be isolated before removal or installation to prevent backplane current disruption.
Q: What airflow capacity does the module provide? A: The dual fans deliver approximately 100 CFM total, with ~50 CFM per individual fan.
Q: Does the diagnostic LED require external wiring? A: No, the LED is integrated into the module front panel and operates automatically when a fan disruption occurs.
Field Installation Guidelines
- Mount the fan module directly into designated 5-slot chassis bays with full connector engagement.
- Ensure airflow paths are unobstructed to maintain cooling efficiency.
- Route 24 VDC supply wiring separately from signal cabling to minimize electromagnetic interference.