Honeywell
📢 100% genuine, extensive in-stock inventory, fast shipping!
Honeywell MC-TDOY23 80366189-175 Digital Output Relay FTA
Honeywell MC-TDOY23 80366189-175 Digital Output Relay FTA
Manufacturer: Honeywell
-
Product No.: MC-TDOY23 80366189-175
Condition:in Stock
Product Type: Digital Output Relay FTA
-
Product Origin: USA
Payment:T/T, Western Union
-
Weight: 1000g
Shipping port: Shanghai/Yiwu/Shenzhen
Warranty: 12 months
Share
Honeywell MC-TDOY23 80366189-175 Digital Output Relay FTA
The Honeywell MC‑TDOY23 80366189‑175, also cataloged as the MC‑TDOY23 digital output relay FTA, operates as a 16‑point relay‑based discrete output interface for AC/DC load switching within Honeywell controller and Safety Manager platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MC‑TDOY23 / 80366189‑175 |
| Brand | Honeywell |
| Origin | Honeywell control and safety platforms |
| Weight | Standard FTA mass (shipping weight varies by assembly) |
| Dimensions | Relay FTA form factor |
| Operating Temp | Industrial ambient range |
| Power Consumption | Logic‑side 24 VDC control input |
| Input Control Voltage | 12–24 VDC (nominal 24 VDC) |
| Output Voltage Range | 5–250 V AC/DC |
| Max Load Current | Up to 10 A per relay contact (typical use ~1 A for extended life) |
| Response Time | 5–10 ms |
| Isolation Rating | 1500 VDC input‑to‑output isolation |
| Channel Count | 16 independent relay output points |
| Relay Life | Mechanical/electrical life up to 1,000,000 cycles |
Channel‑to‑Channel Isolation in Honeywell Relay FTAs
Relay FTAs in Honeywell systems maintain deterministic separation between logic‑side control voltage and field‑side load circuits. The MC‑TDOY23 applies 1500 VDC isolation to prevent inductive spikes from propagating into the controller backplane. This isolation behavior aligns with Honeywell’s broader process‑control design practices, including predictable boundaries used in 4‑20 mA HART loop protocol and Fieldbus/Profibus gateway modules. Independent relay channels ensure that AC/DC loads do not cross‑couple during switching events.
Frequently Asked Questions
Q: Can the relay FTA switch both AC and DC loads? A: Yes. The output stage supports 5–250 V AC/DC across all 16 relay channels.
Q: Is there electrical isolation between the logic input and relay output? A: Yes. The module provides 1500 VDC isolation to protect the controller from field transients.
Q: Does relay life depend on load current? A: Yes. Although contacts can support up to 10 A, operating near 1 A significantly extends mechanical and electrical life.
Field Installation Guidelines
- Maintain correct polarity on the 24 VDC logic‑side control wiring.
- Route AC/DC load wiring separately from logic conductors to reduce inductive coupling.
- Observe recommended load current limits to maximize relay life.
- Verify isolation and switching behavior using system diagnostics after installation.
- Ensure cabinet airflow prevents thermal accumulation around relay assemblies
Hot Tags :

- Choosing a selection results in a full page refresh.
- Opens in a new window.